MODEL | LRS-350-12 | LRS-350-24 | |
OUTPUT | DC VOLTAGE | 12V | 24V |
RATED CURRENT | 29A | 14.6A | |
CURRENT RAGE | 0~29.0A | 0~14.6A | |
RATED POWER | 350W | 350W | |
RIPPLE&NOISE(max.)(Note 2) | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ.RANGE | 10.2~13.8V | 21.6~28.8V | |
VOLTAGE TOLERANCE(Note 3) | ±1.0% | ±1.0% | |
LINE REGULATION(Note 4) | ±0.5% | ±0.5% | |
LOAD REGULATION(Note 5) | ±0.5% | ±0.5% | |
SETUP ,RISE TIME | 500ms,30ms/230VAC 500ms,30ms/115VAC at full load | ||
HOLD UP TIME (Typ.) | 16ms/230VAC 12ms/115VAC at full load | ||
INPUT | VOLTAGE RANGE | 85~132VAC /170~264VAC by switch 240~370VDC (switch on 230VAC) | |
FREQUENCY RANGE | 47~63Hz | ||
EFFICIENCY | 85.00% | 88.00% | |
AC CURRENT(Typ.) | 6.8A/115VAC 3.4A/230VAC | ||
INRUSH CURRENT (Typ.) | COLD STAR 60A/230VAC | ||
LEAKAGE CURRENT | <2.0mA/240VAC | ||
PROTECTION | OVER LOAD | 110~140% rated output power | |
Protection type :Hiccup mode,recovers automatically after fault condition is removed | |||
OVER VOLTAGE | 13.8~16.2V | 28.8~33.6V | |
Protection type :Shut down o/p voltage , re-power on to recover | |||
OVER TEMPERATURE | Shut down o/p voltage , re-power on to recover | ||
ENVIROMENT | WORKING TEMP. | -30~+70℃ | |
WORKING HUMIDITY | 20~90% RH non-condensing | ||
STORAGE TEM.,HUMIDITY | -40~+85℃ , 10~95% RH | ||
TEMP.COEFFICIENT | ±0.03%/℃ (0~50℃) | ||
VIBRATION | 10~500Hz , 5G 10min./1cycle , 60min. each along X,Y,Z axes | ||
SAFETY & EMC (Note 7) | SAFETY STANDARDS | EN60950-1 | |
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/ P-FG:1.5 KVAC O/P-FG:0.5 KVAC | ||
ISOLATION RESISTANCE | I/ P-O/P, I/ P-FG, O/P-FG:100M Ohms / 500VDC / 25 ℃/ 70% RH | ||
EMC EMISSION | Compliance to EN55022 (CISPR22) ,EN55024 | ||
EMC IMMUNITY | Compliance to EN61000-3-2,3 | ||
OTHERS | MTBF | 601K h r s min. MIL-HDBK-217F ( 25 ℃) | |
DIMENSION | 215*115*30mm (L*W*H) | ||
PACKING | 0.67Kg ; 30pcs/20.6Kg/38*25*39CM | ||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC direc ves. For guidance on how to perform these EMC tests, please refer to EMI tes ng of component power supplies. 8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m (6500ft). |