Model | LRS-50-5 | LRS-50-12 | LRS-50-15 | LRS-50-24 | LRS-50-36 | LRS-50-48 |
Dc output voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated output current | 10A | 4.2A | 3.4A | 2.2A | 1.45A | 1.1A |
Output current rage | 0-10A | 0-4.2A | 0-3.4A | 0-2.2A | 0-1.45A | 0-1.1A |
Rated Power | 50W | 50.4W | 51W | 52.8W | 52.2W | 52.8W |
Wave and noise | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
Voltage ADJ. range | 4.5-5.5V | 10.2-13.8V | 2013-05-18 | 21.6-28.8V | 32.4-39.6V | 43.2-52.8V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 83,00% | 86,00% | 88,00% | 88,00% | 89,00% | 90,00% |
AC input voltage range | AC85~264V 47~63Hz;120~373VDC | |||||
Input current | 0.95A/115V 0.56A/230V | |||||
AC INnrush current | Cold-start 45A/230V | |||||
Overload proctection | 110%~150% Potection type: Hiccp mode,recobers automatically after condition recoverd | |||||
Over-voltage protection | 5.9-7.3V | 13.8-16.2V | 18.75-21.75V | 28.8-33.6V | 41.4-48.6V | 55.2-64.8V |
Potection type :Shut down o/p voltage,re-power on to recover | ||||||
Setup rise time | 1000ms,30ms/230VAC 2000ms,30ms/115VAC at full lod | |||||
Hold up time | 30ms/230VAC ,12ms/115VAC at full lod | |||||
Withstand voltage | I/P-O/P:3.75KVAC,I/P-FG:2KVAC,O/P-FG: 1.25KVAC | |||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/ 500VDC /25°C/70%RH | |||||
Working temperature | -30°C~+70°C | |||||
Overall dimension | 99*82*30mm | |||||
Safety standards | Meet ULGB4943 UL60950 EN60950 | |||||
EMC standards | Meet EN55022,EN61000-3-2,EN61000-3-3,EN55024 GB9254 Class B | |||||
Weight | 0.23Kgs |