DC motor PWM-es vezérlő áramkör, állítható biztonsági áramkorlát funkcióval.
Jellemzők:
- Input voltage:12V - 36V
- Rated current: 10A
- Input voltage abs max : DC 10V - 40V
- Abs.Max Current: 15A
- Output voltage : 0V - input Volt(adjustable)
- control speed range: 0%-100%
- PWM Frequency: 21Khz
- Output power: 360W(max)
- over current protection:1-10A adjustable(gyárilag 1A-re tekerve)
- cable length: 40cm
- Size :85*54*27mm
- weight: 68g
STANDARD FEATURES: Provide smooth variable speed capability for DC motor Adjustable current limit Include Power-on LED and current-limit-protected alarm LED TECHNICAL PARAMETERS: Input supply voltage | The range of 12V to 36V | Load current (continuous) | 10A | Speed adjustment | 100KΩ potentiometer; variable speed control | Duty cycle range | Adjustable 0 to 100% | Internal operating frequency | 21kHz | Current limit | Adjustable 1A to 10A | LED display | Power-on LED (green); Current-limit-protected alarm LED (red) | Specification | 85.5mm*54mm*27mm / about 70g |
CURRENT LIMIT ADJUSTMENT: When the red alarm LED is lighting, the trim pot should be reset as follow: 1. Turn off the power. 2. Adjust the trim pot until the desired maximum current is reached. 3. Wait for about 3 seconds, than reset the power . IN CASE OF DIFFICULTY If a newly installed control will not operate, it is likely that a terminal or connection is loose. Check to make sure connections are secure and correct. If the control is still inoperative, refer to the following chart for reference: PROBLEM | POSSIBLE CAUSE(S) | CORRECTIVE ACTION | Motor doesn’t run | Incorrect or no power Potentiometer set at zero Worn motor brushes Current limit set too low | Install proper service Rotate the potentiometer fully CW Replace motor brushes Adjust current limit trim pot CW | Motor runs at “full speed” uncontrollable | Loose potentiometer connections Possible control failure | Secure all connections Contact us returns policy | Motor rotates in wrong direction | Motor wire hooked up backwards | | Motor stalls under a light load | Current limit trim pot improperly adjusted | Adjust the trim pot properly |
|