Trigger signal source: high initialization trigger (3.0V~24V), trigger trigger (0.0V~0.2V), switch control (passive switch).
Size:98 x 55 x 44mm
Feature:
1. DIGITAL DISPLAY: This timer relay is equipped with LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical.
2. EASY TO TRIGGER: Support button triggering control, high and low level triggering, switch quantity control, support NPN, PNP sensor access, suitable for most occasion.
3. ADDED SLEEP MODE: If there is no operation for about 5 minutes and the LCD backlit will automatically turn off, can be waked up with any button.
4. POWER FAILURE MEMORY: You can set different OP, CL, and LOP parameters, which are independent of each other and saved separately. All set parameters are automatically saved after power down.
5. USER FRIENDLY: This time delay relay has one key pause function, with reverse connection protection, more convenient and safe to use.
Working Mode:
P0: After the signal is triggered, the relay conducts for OP time and then disconnects; During the OP time, signal triggers again, invalid
P1: After the signal is triggered, the relay conducts for OP time and then disconnects; During the OP time, signal triggers again, re timing
P2: After the signal is triggered, the relay conducts for OP time and then disconnects; During the OP time, signal triggers again, reset, relay disconnects, the timing stops
P3: After the signal is triggered, the relay disconnects for CL time, and then the relay conducts
P4: Give trigger signal, the relay conducts for OP time, and disconnects for CL time, then cycle the above actions. Within the cycle, give the signal again to recover the initial state and stop timing. The number of cycles (LOP) can be set. At the end of the cycle, the relay will remain disconnected
P5: Give trigger signal, the relay disconnects for CL time, and conducts for OP time, then cycle the above actions. Within the cycle, give the signal again to recover the initial state and stop timing. The number of cycles (LOP) can be set. At the end of the cycle, the relay will remain conductive
P6: After powering on, there is no need to trigger the signal. The relay conducts for OP time and disconnects for CL time, cycle the above actions. The number of cycles (LOP) can be set. At the end of the cycle, the relay will remain disconnected
P7: After powering on, there is no need to trigger the signal. The relay disconnects for CL time, and conducts for OP time, cycle the above actions. The number of cycles (LOP) can be set. At the end of the cycle, the relay will remain conductive
P8: Signal holding function: If there is a trigger signal, the timing will be reset and the relay will remain conductive. When the signal disappears, disconnects the relay after timing OP. During the timing period, if there is another signal, the timing will be reset
P9: Signal holding function: If there is a trigger signal, the timing will be reset and the relay will remain disconnected. When the signal disappears, conducts the relay after timing CL. During the timing period, if there is another signal, the timing will be reset
Parameters:
1: Working Voltage: 6-30V power supply
2: Trigger Signal Sources: High level trigger (3.0-24V), low level trigger (0.0-0.2V), switch quantity control (passive switch)
3: Output Capacity: Can control devices within DC30V 30A or AC220V 30A
4: Static Current: 15mA; Working Current: 50-130mA
5: Service Life: Greater than 100,000 times; Working Temperature: -40℃ to 85℃
6: Equipped with optocoupler isolation, enhanced anti interference ability, industrial grade circuit board, set parameters, always remember after power outage.
Timing Range:
0.01 seconds (minimum) to 9999 minutes (maximum), continuously adjustable
How to select timing range:
On the OP or CL parameter modification interface, briefly press the pause button to select the timing range
XXXX: No decimal point, with a timing range of 1 second to 9999 seconds
XXX.X: Decimal point to the tenth place, with a timing range of 0.1 seconds to 999.9 seconds
XX.XX: Decimal point to the hundredth place, with a timing range of 0.01 seconds to 99.99 seconds
X.X.X.X: The decimal point is fully lit, with a timing range of 1 minute to 9999 minutes
For example, if you want to set OP to 3.2 seconds, then move the decimal point to the tenth place and the LCD will display 003.2
Parameter Description: OP conduction time, CL disconnection time, LOP number of cycles (1-9999 times, ---- represents unlimited cycles)
Parameter Settings:
a) Press and hold the setting button to enter the setting interface
b) Firstly, set the working mode, with flashing reminders. Set the working mode by briefly pressing the increase or decrease button
c) Short press the setting button, select the working mode, and enter the system parameter settings
d) In the system parameter setting interface, short press the setting button to switch between the system parameters to be modified, and short press or long press increase or decrease button to modify (Note: Short press of the setting button is invalid in P0 to P3 P8 P9 modes)
e) On the OP CL parameter modification interface, briefly press the pause button to switch the timing unit (1s 0.1s 0.01s 1min)
f) After setting all parameters, long press the setting button to save the parameter settings and exit the setting interface
Additional Features:
a) Automatic sleep function: In the operation interface (P0 to P7 modes), press and hold the pause button to activate or deactivate the automatic sleep function (L-P selects on to activate the sleep function, no operation for about five minutes, the LCD backlit automatically turns off, the system runs normally, any button wakes up; off to deactivate the sleep function)
b) Parameter viewing: In the running interface, short press the SET key to display the current parameter settings of the system, which does not affect the normal operation of the system
c) Display content switching: In P4 to P7 modes, switch the display content (running time or number of cycles) by briefly pressing the DOWN key
Package List:
1 x Timer Relay
1 x Connection Cable